HPE G2 Metered Modular Horizontal True 0U - power distribution unit - 4900 VA

SKU P9R51A
Product Description:HPE G2 Metered Modular Horizontal True 0U - power distribution unit - 4900 VA
Device Type:Power distribution unit - rack-mountable
Cord Length:30.5 cm
Rack Size:1U
Weight:7.03 kg
Localisation:Japan, North America
Input Wiring:1-phase
16-07-2025
  • Specifications
  • Description
General
Device Type:Power distribution unit - rack-mountable
Height (Rack Units):1U
Cord Length:30.5 cm
Localisation:Japan, North America
Power Device
Input Voltage:AC 208 V
Input Voltage Range:AC 200 - 208 V
Input Wiring:1-phase
Input Connectors:1 x power NEMA L6-30
Power Output Connectors Details:6 x power IEC 60320 C19
Output Voltage:AC 200-240 V
Max Electric Current:24 A
Power Capacity:4900 VA
Circuit Protection:Circuit breaker
Miscellaneous
Included Accessories:Tie wraps
Cables Included:Power cable 30.5 cm
Rack Mounting Kit:Included
Compliant Standards:CSA, UL, VCCI, CB, FCC, WEEE, ICES
Environmental Parameters
Min Operating Temperature:10 °C
Max Operating Temperature:60 °C
Humidity Range Operating:10 - 90%
Dimensions & Weight
Width:44.4 cm
Depth:27 cm
Height:4.35 cm
Weight:7.03 kg
Compatibility Information
Designed For:HPE Synergy 12000 Frame
vis mere
Do you need rack level power monitoring over the network? With billing grade accuracy, HPE G2 Metered Power Distribution Units (PDU) are an excellent choice for data centers wanting to make the most of circuit capacity or for co-location facilities needing to precisely track power usage for billing purposes. The G2 Metered PDUs offer load segment power metering and have a low profile single piece design with multiple mounting options and ease of access to rear devices for maintenance. Designed for HPE racks but also work in a large variety of third party racks as well using standard button and keyhole mounting. They can be installed on either side of the rack with outlets facing the back of the rack for easy access and improved clearance. Also for higher power density they can be installed side by side on both sides of the rack with the outlets facing in towards the center of the rack. HPE G2 Metered PDUs are backed by HPE's limited 3-year warranty.
  • Rack-mountable form factor for easy integration
  • Includes 6 power IEC 60320 C19 output connectors
  • Supports a wide operating temperature range from 10°C to 60°C
  • Comes with a rack mounting kit for convenient installation




The technical details come from 3rd party. edgemo is not responsible for any errors.