APC Switched Rack PDU 2G Zero U - power distribution strip

SKU AP8958
Product Description:APC Switched Rack PDU 2G Zero U - power distribution strip
Device Type:Power distribution strip - rack-mountable
Weight:3.2 kg
Input Voltage:AC 200/208/230 V
Output Voltage:AC 200/208/230 V
Input Connectors:1 x power IEC 60320 C20
Output connectors:1 x power IEC 60320 C19 ¦ 7 x power IEC 60320 C13
In Stock(5)
  • Specifications
  • Description
General
Device Type:Power distribution strip - rack-mountable
Colour:Black
Power Device
Input Voltage:AC 200/208/230 V
Input Voltage Range:AC 100 - 240 V
Frequency Required:50/60 Hz
Input Connectors:1 x power IEC 60320 C20
Power Output Connectors Details:1 x power IEC 60320 C19 ¦ 7 x power IEC 60320 C13
Output Voltage:AC 200/208/230 V
Max Electric Current:16 A
Networking
Remote Management Interface:RS-232
Remote Management Protocol:SNMP, Telnet, HTTP
Expansion / Connectivity
Interfaces:1 x management
Miscellaneous
Cables Included:Power cable ¦ Serial cable - external
Rack Mounting Kit:Included
Features:LCD display
Compliant Standards:UL, cUL, EN 61000-3-2, EN55022, ICES-003, VDE, VCCI Class A ITE, EN 61000-3-3, EN55024, RoHS, FCC Part 15 A, PSE Mark, REACH
Manufacturer Warranty
Service & Support:Limited warranty - 2 years
Environmental Parameters
Min Operating Temperature:-5 °C
Max Operating Temperature:45 °C
Humidity Range Operating:5 - 95%
Dimensions & Weight
Width:5.6 cm
Depth:4.6 cm
Height:98.8 cm
Weight:3.2 kg
Dimensions & Weight (Shipping)
Shipping Width:16.5 cm
Shipping Depth:11.4 cm
Shipping Height:113 cm
Shipping Weight:4.8 kg
Compatibility Information
Designed For:P/N: AP6221CH, AR2200, AR2280, AR2487G, AR3100G, AR3100TAA, AR3100W, AR3103SP, AR3105SP, AR3105W, AR3106SP, AR3107G, AR3107SP, AR3140G, AR3140W, AR3150SP, AR3150W, AR3155SP, AR3155W, AR3157SP, AR3180G, AR3300G, AR3300SP, AR3300W, AR3305SP, AR3305W, AR3307SP, AR3307W, AR3340G, AR3340W, AR3350SP, AR3350W, AR3355SP, AR3355W, AR3357SP, AR3357X674, AR4024SP, AR4024SPX429, AR4024SPX431, AR4024SPX432, AR4038IX432, AR9300SP, AR9300SP-R, AR9307SP, AR9307SP-R, DLT3000RMI2U, NBES0302, NBPD0160A, NBPD0180, NBWL0355A, NBWL0356A, SMC1000-BR, SMC1000I-2UC, SMC1000I-BR, SMC1000IC, SMC15002U-BR, SMC1500-BR, SMC1500I2U-BR, SMC1500I-2UC, SMC1500I-BR, SMC1500IC, SMC2000I, SMC2000I-2U, SMC3000I, SMC3000RMI2U, SMT1500RM1U, SMT2200I-AR, SMT2200IC, SMT2200R2I-AR, SMT2200RM2UC, SMT2200RMI2UC, SMT2200RMI2UNC, SMT3000I2U-BR, SMT3000I-AR, SMT3000IC, SMT3000R2I-6W, SMT3000R2I-AR, SMT3000RM2UC, SMT3000RMI2UC, SMT3000RMI2UNC, SMX1000C, SMX1000US, SMX1500RM2UC, SMX1500RM2UCNC, SMX1500RMNCUS, SMX1500RMUS, SMX2000LVNCUS, SMX2000LVUS, SMX2200HVNC, SMX2200R2HVNC, SMX2200RMHV2U, SMX2200RMLVUS, SMX3000HV-BR, SMX3000HVT, SMX3000HVTUS, SMX3000LV2U-BR, SMX3000LVNCUS, SMX3000LVUS, SMX3000RMLVUS, SMX3KRMLVNCUS, SMX750C, SMX750CNC, SMX750US, SPD10KCBL, SPD20KCBL, SRT1000RMXLA, SRT1000RMXLA-NC, SRT1000RMXLI, SRT1000RMXLI-NC, SRT10KRMXLI, SRT10KRMXLT-IEC, SRT10KXLI, SRT10KXLT-IEC, SRT10RMXLIX806, SRT1500RMXLA, SRT1500RMXLA-NC, SRT1500XLI, SRT2200RMXLI, SRT2200RMXLI-NC, SRT2200XLI, SRT2200XLI-KR, SRT3000RMXLI, SRT3000RMXLI-NC, SRT3000RMXLW-IEC, SRT3000XLI, SRT3000XLW-IEC, SRT5KRMXLI, SRT5KRMXLI-6W, SRT5KRMXLIM, SRT5KRMXLT, SRT5KRMXLT-IEC, SRT5KRMXLTUS, SRT5KRMXLW-HW, SRT5KRMXLW-TW, SRT5KXLI, SRT6KRMXLI, SRT6KRMXLI-6W, SRT6KRMXLIM, SRT6KRMXLT, SRT6KRMXLT-IEC, SRT6KXLI, SRT6KXLT-IEC, SRT8KRMXLI, SRT8KRMXLT, SRT8KRMXLT-IEC, SRT8KXLI, SRT8KXLT-IEC, SUA2200ICH-45, SUA3000ICH-45, SUA3000I-IN, SURT3000XLI-ET, SURT5000XLIX438, SURTD5000XLI-ET, SYAF16KRMICH, SYAF8KRMTX424
vis mere
APC Switched Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and active monitoring. The output and input connections are ((42) C13, (6) C19 Remote outlet level controls allow power on/off functionality for power recycling to remotely reboot equipment and restrict unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and low-profile circuit breakers. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched Rack PDUs through secure Web, SNMP, or Telnet Interfaces and are complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager.
  • Network Management Capabilities
  • Remote Individual Outlet Control
  • Alarm Thresholds
  • Local Current Monitoring Display
  • Power Delays
  • Load indicator LED
  • Flash Upgradeable
  • Integrates with StruxureWare Data Center Expert




The technical details come from 3rd party. edgemo is not responsible for any errors.

Loading...