APC Metered Rack PDU ZeroU 2G - power distribution unit
SKU AP8453
Product Description: | APC Metered Rack PDU ZeroU 2G - power distribution unit |
Device Type: | Power distribution unit - rack-mountable |
Rack Size: | 0U |
Weight: | 8.21 kg |
Input Voltage: | AC 200/208/230 V |
Output Voltage: | AC 230 V |
Input Connectors: | 1 x power IEC 60309 32A |
- Specifications
- Description
General | |
Device Type: | Power distribution unit - rack-mountable |
Height (Rack Units): | 0U |
Colour: | Black |
Power Device | |
Input Voltage: | AC 200/208/230 V |
Frequency Required: | 50/60 Hz |
Input Connectors: | 1 x power IEC 60309 32A |
Power Output Connectors Details: | 21 x power IEC 60320 C13 ¦ 3 x power IEC 60320 C19 |
Output Voltage: | AC 230 V |
Max Electric Current: | 32 A |
Networking | |
Remote Management Interface: | Ethernet |
Remote Management Protocol: | SNMP, Telnet |
Expansion / Connectivity | |
Interfaces: | 1 x management (Ethernet) - RJ-45 |
Miscellaneous | |
Cables Included: | Power cable 3.05 m |
Features: | LCD display, firmware upgradable |
Compliant Standards: | EN 61000-3-2, VDE, EN 61000-3-3, EN55024, EN55022 Class A, RoHS, REACH |
Manufacturer Warranty | |
Service & Support: | Limited warranty - 2 years |
Environmental Parameters | |
Min Operating Temperature: | -5 °C |
Max Operating Temperature: | 45 °C |
Humidity Range Operating: | 5 - 95% |
Dimensions & Weight | |
Width: | 5.6 cm |
Depth: | 5.1 cm |
Height: | 182.9 cm |
Weight: | 8.21 kg |
Dimensions & Weight (Shipping) | |
Shipping Width: | 16.3 cm |
Shipping Depth: | 11.7 cm |
Shipping Height: | 203.7 cm |
Shipping Weight: | 10.48 kg |
Compatibility Information | |
Designed For: | P/N: AP5607, AP7950B, AR2200, AR2280, AR2400, AR2400FP1, AR2401, AR2407, AR2480, AR2487, AR2487G, AR2500, AR2507, AR2580, AR2587, AR3100G, AR3100TAA, AR3100W, AR3100X609, AR3100X610, AR3100X617, AR3105, AR3105SP, AR3105W, AR3107G, AR3107SP, AR3107X609, AR3107X610, AR3107X617, AR3150SP, AR3150W, AR3150X609, AR3150X610, AR3150X617, AR3155, AR3155SP, AR3155W, AR3157SP, AR3157X609, AR3157X610, AR3157X617, AR3180G, AR3300G, AR3300SP, AR3300W, AR3300X609, AR3300X610, AR3300X617, AR3305, AR3305SP, AR3305W, AR3307SP, AR3307W, AR3307X609, AR3307X610, AR3307X617, AR3350SP, AR3350W, AR3350X609, AR3350X610, AR3350X617, AR3355, AR3355SP, AR3355W, AR3357SP, AR3357X609, AR3357X610, AR3357X617, AR3357X674, NBES0302, NBPD0160A, NBPD0171, NBPD0172, NBPD0180, NBWL0355A, NBWL0356A, SMC1000, SMC1000-2U, SMC1000-BR, SMC1000I, SMC1000I-2U, SMC1000I-2UC, SMC1000I-BR, SMC1000IC, SMC1500, SMC15002U-BR, SMC1500-BR, SMC1500I, SMC1500I-2U, SMC1500I2U-BR, SMC1500I-2UC, SMC1500I-BR, SMC1500IC, SMC2000I-2U, SMC3000RMI2U, SMT1500RM1U, SMT1500RM2U, SMT1500RMI1U, SMT2200RM2UC, SMT3000I2U-BR, SMT3000RM2U, SMT3000RM2UC, SMT3000RMT2U, SMT750RM2U, SMX1000US, SMX1500RMNCUS, SMX1500RMUS, SMX2000LV, SMX2000LVNC, SMX2000LVNCUS, SMX2000LVUS, SMX2000RMLV2U, SMX2200HV, SMX2200HVNC, SMX2200R2HVNC, SMX2200RMHV2U, SMX2200RMLV2U, SMX2200RMLVUS, SMX3000HV, SMX3000HV-BR, SMX3000HVNC, SMX3000HVT, SMX3000HVTUS, SMX3000LV, SMX3000LV2U-BR, SMX3000LVNC, SMX3000LVNCUS, SMX3000LVUS, SMX3000RMHV2U, SMX3000RMHV2UNC, SMX3000RMLV2U, SMX3000RMLV2UNC, SMX3000RMLVUS, SMX3KRMLVNCUS, SMX750-NMC, SMX750US, SRT1000RMXLA, SRT1000RMXLA-NC, SRT1000RMXLI, SRT1000RMXLI-NC, SRT10KRMXLI, SRT10RMXLIX806, SRT1500RMXLA, SRT1500RMXLA-NC, SRT5KRMXLT, SRT5KRMXLT-IEC, SRT5KRMXLTUS, SRT5KRMXLW-HW, SRT5KRMXLW-TW, SRT6KRMXLI, SRT6KRMXLT, SRT6KRMXLT-IEC, SRT8KRMXLI, SRT8KRMXLT, SRT8KRMXLT-IEC, SUA3000RMXL3U-BR, SURT3000XLI-ET, SURT5000XLIX438, SYA12K16RMICH, SYA16K16RMICH, SYA8K16RMICH, SYAF16KRMICH |
APC Metered by Outlet Rack Power Distribution Units (PDUs) provide individual outlet power metering to enable energy optimization and circuit protection. Current metering provides real-time remote monitoring of connected loads. Metered by Outlet Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered by Outlet Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered by Outlet Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
- Integrates with StruxureWare data center expert
- Local current monitoring display
- Alarm thresholds
- Network management capabilities
- Flash upgradeable
- Metering-by-outlet capability
- Load indicator LED