APC Metered Rack PDU ZeroU 2G - power distribution strip
SKU AP8853
Product Description: | APC Metered Rack PDU ZeroU 2G - power distribution strip |
Device Type: | Power distribution strip - rack-mountable |
Rack Size: | 0U |
Weight: | 6.9 g |
Input Voltage: | AC 200/208/230 V |
Output Voltage: | AC 230 V |
Input Connectors: | 1 x power IEC 60309 32A |
- Specifications
- Description
General | |
Device Type: | Power distribution strip - rack-mountable |
Height (Rack Units): | 0U |
Colour: | Black |
Power Device | |
Input Voltage: | AC 200/208/230 V |
Input Voltage Range: | AC 220 - 240 V |
Input Connectors: | 1 x power IEC 60309 32A |
Power Output Connectors Details: | 36 x power IEC 60320 C13 ¦ 6 x power IEC 60320 C19 |
Output Voltage: | AC 230 V |
Max Electric Current: | 32 A |
Circuit Protection: | Circuit breaker |
Networking | |
Remote Management Protocol: | SNMP, Telnet, HTTP |
Miscellaneous | |
Cables Included: | Serial cable - external ¦ Power cable 3 m |
Rack Mounting Kit: | Included |
Features: | LCD display, thermal monitoring, humidity monitoring, overload protection |
Compliant Standards: | VDE, IEC 60950, RoHS, REACH |
Manufacturer Warranty | |
Service & Support: | Limited warranty - 2 years |
Environmental Parameters | |
Min Operating Temperature: | 5 °C |
Max Operating Temperature: | 45 °C |
Humidity Range Operating: | 5 - 95% |
Dimensions & Weight | |
Width: | 5.6 cm |
Depth: | 4.4 cm |
Height: | 179 cm |
Weight: | 6.9 g |
Dimensions & Weight (Shipping) | |
Shipping Width: | 46.2 cm |
Shipping Depth: | 10.7 cm |
Shipping Height: | 200 cm |
Shipping Weight: | 8.6 kg |
Compatibility Information | |
Designed For: | P/N: AP5607, AP6453CH, AR2200, AR2280, AR2400, AR2400FP1, AR2401, AR2407, AR2480, AR2487, AR2487G, AR2500, AR2507, AR2580, AR2587, AR3100G, AR3100TAA, AR3100W, AR3100X609, AR3100X610, AR3100X617, AR3105, AR3105SP, AR3105W, AR3107G, AR3107SP, AR3107X609, AR3107X610, AR3107X617, AR3130, AR3140G, AR3140W, AR3150SP, AR3150W, AR3150X609, AR3150X610, AR3150X617, AR3155, AR3155SP, AR3155W, AR3157SP, AR3157X609, AR3157X610, AR3157X617, AR3180G, AR3300G, AR3300SP, AR3300W, AR3300X609, AR3300X610, AR3300X617, AR3305, AR3305SP, AR3305W, AR3307SP, AR3307W, AR3307X609, AR3307X610, AR3307X617, AR3340, AR3340G, AR3340W, AR3347, AR3350SP, AR3350W, AR3350X609, AR3350X610, AR3350X617, AR3355, AR3355SP, AR3355W, AR3357SP, AR3357X609, AR3357X610, AR3357X617, AR3357X674, NBES0302, NBPD0160A, NBPD0171, NBPD0172, NBPD0180, NBWL0355A, NBWL0356A, SMC1000, SMC1000-2U, SMC1000-BR, SMC1000I, SMC1000I-2U, SMC1000I-2UC, SMC1000I-BR, SMC1000IC, SMC1500, SMC15002U-BR, SMC1500-BR, SMC1500I, SMC1500I-2U, SMC1500I2U-BR, SMC1500I-2UC, SMC1500I-BR, SMC1500IC, SMC2000I-2U, SMC3000RMI2U, SMT1500RM1U, SMT1500RM2U, SMT1500RMI1U, SMT2200RM2UC, SMT3000I2U-BR, SMT3000RM2UC, SMT3000RMT2U, SMX1000US, SMX1500RMNCUS, SMX1500RMUS, SMX2000LV, SMX2000LVNC, SMX2000LVNCUS, SMX2000LVUS, SMX2200HV, SMX2200HVNC, SMX2200R2HVNC, SMX2200RMHV2U, SMX2200RMLV2U, SMX2200RMLVUS, SMX3000HV, SMX3000HV-BR, SMX3000HVNC, SMX3000HVT, SMX3000HVTUS, SMX3000LV, SMX3000LV2U-BR, SMX3000LVNC, SMX3000LVNCUS, SMX3000LVUS, SMX3000RMHV2U, SMX3000RMHV2UNC, SMX3000RMLVUS, SMX3KRMLVNCUS, SMX750-NMC, SMX750US, SRT1000RMXLA, SRT1000RMXLA-NC, SRT1000RMXLI, SRT1000RMXLI-NC, SRT10KRMXLI, SRT10RMXLIX806, SRT1500RMXLA, SRT1500RMXLA-NC, SRT5KRMXLT, SRT5KRMXLT-IEC, SRT5KRMXLTUS, SRT5KRMXLW-HW, SRT5KRMXLW-TW, SRT6KRMXLI, SRT6KRMXLT, SRT6KRMXLT-IEC, SRT8KRMXLI, SRT8KRMXLT, SRT8KRMXLT-IEC, SUA3000RMXL3U-BR, SURT3000XLI-ET, SURT5000XLIX438, SYA12K16RMICH, SYA16K16RMICH, SYA8K16RMICH, SYAF16KRMICH |
APC Metered Rack PDUs distribute reliable rack power distribution via a single input with multiple output receptacles. Real-time remote monitoring and user-defined alarms help prevent potential circuit overloads that can cause accidental power loss to critical equipment. Easily access, configure, and manage this metered PDU from remote locations. A network management interface provides standards-based management via Web, SNMP, and Command Line Interface. This Metered PDU from APC provides (36) IEC 60320 C13 and (6) IEC 60320 C19 outlets to supply power to rack equipment. Locking IEC receptacles enable locking power cord compatibility to reduce the probability of accidentally disconnecting cords and dropping loads. Volts, amps, real power (kW), and energy (kWh) data is provided to support energy management. An embedded log memory to reports historic metered data. Display details current, power, and voltage measurements and offers local user access. An environmental monitoring port for external temperature/humidity monitoring is available (sensor sold separately model AP9335T or AP9335TH). Easily mount this vertical PDU in racks or enclosures. It occupies zero U of valuable rack space, which allows space for more equipment in the rack. This vertical PDU does not require additional tools to mount into APC NetShelter Enclosures. Enables a quick recovery from overload events and breakers are ultra-low profile. Packaging Includes PDU, Installation guide, Rack Mounting brackets, Safety guide, Serial configuration cable.
- Remote management capabilities
- Local current monitoring display
- Alarm thresholds
- Load indicator LED
- Integrates with StruxureWare data center expert
- Single input power source