APC Metered Rack PDU - power distribution unit - 10 kW
SKU AP8868
Product Description: | APC Metered Rack PDU - power distribution unit - 10 kW |
Device Type: | Power distribution unit - rack-mountable |
Rack Size: | 0U |
Weight: | 8.5 kg |
Localisation: | Canada, United States |
Input Wiring: | 3-phase |
Input Voltage: | AC 208 V |
- Specifications
- Description
General | |
Device Type: | Power distribution unit - rack-mountable |
Height (Rack Units): | 0U |
Colour: | Black |
Localisation: | Canada, United States |
Power Device | |
Input Voltage: | AC 208 V |
Input Wiring: | 3-phase |
Frequency Required: | 50/60 Hz |
Input Connectors: | 1 |
Power Output Connectors Details: | 36 x power IEC 60320 C13 ¦ 6 x power IEC 60320 C19 |
Output Voltage: | AC 208 V |
Max Electric Current: | 35 A |
Power Capacity: | 10 kW |
Circuit Protection: | Circuit breaker |
Networking | |
Remote Management Interface: | Ethernet 10/100, RS-232 |
Remote Management Protocol: | SNMP, Telnet, HTTP |
Expansion / Connectivity | |
Interfaces: | 1 x management (RS-232) ¦ 1 x management (Ethernet) - RJ-45 |
Miscellaneous | |
Cables Included: | Power cable - integrated - 1.8 m |
Rack Mounting Kit: | Included |
Features: | Current meter, overload protection |
Compliant Standards: | FCC Class A certified, UL, cUL, ICES-003, VCCI Class A ITE, FCC Part 15, RoHS Exemption 7b, UL 60950-1, CSA C22.2 No. 60950-1-03 |
Manufacturer Warranty | |
Service & Support: | Limited warranty - 2 years |
Environmental Parameters | |
Min Operating Temperature: | 0 °C |
Max Operating Temperature: | 50 °C |
Humidity Range Operating: | 5 - 95% |
Dimensions & Weight | |
Width: | 5.6 cm |
Depth: | 5.1 cm |
Height: | 183 cm |
Weight: | 8.5 kg |
Dimensions & Weight (Shipping) | |
Shipping Width: | 17 cm |
Shipping Depth: | 11.2 cm |
Shipping Height: | 205 cm |
Shipping Weight: | 11.4 kg |
Compatibility Information | |
Designed For: | P/N: AP7950B, AR2200, AR2280, AR2400, AR2400FP1, AR2401, AR2407, AR2480, AR2487, AR2487G, AR2500, AR2507, AR2580, AR2587, AR3100G, AR3100TAA, AR3100W, AR3100X609, AR3100X610, AR3100X617, AR3105, AR3105SP, AR3105W, AR3107G, AR3107SP, AR3107X609, AR3107X610, AR3107X617, AR3130, AR3140G, AR3140W, AR3150SP, AR3150W, AR3150X609, AR3150X610, AR3150X617, AR3155, AR3155SP, AR3155W, AR3157SP, AR3157X609, AR3157X610, AR3157X617, AR3180G, AR3300G, AR3300SP, AR3300W, AR3300X609, AR3300X610, AR3300X617, AR3305, AR3305SP, AR3305W, AR3307SP, AR3307W, AR3307X609, AR3307X610, AR3307X617, AR3340, AR3340G, AR3340W, AR3350SP, AR3350W, AR3350X609, AR3350X610, AR3350X617, AR3355, AR3355SP, AR3355W, AR3357SP, AR3357X609, AR3357X610, AR3357X617, AR3357X674, NBES0302, NBPD0160A, NBPD0171, NBPD0172, NBPD0180, NBWL0355A, NBWL0356A, SMC1000, SMC1000-2U, SMC1000-BR, SMC1000I, SMC1000I-2U, SMC1000I-2UC, SMC1000I-BR, SMC1000IC, SMC1500, SMC15002U-BR, SMC1500-BR, SMC1500I, SMC1500I-2U, SMC1500I2U-BR, SMC1500I-2UC, SMC1500I-BR, SMC1500IC, SMC2000I-2U, SMC3000RMI2U, SMT1500RM1U, SMT1500RM2U, SMT1500RMI1U, SMT2200RM2UC, SMT3000I2U-BR, SMT3000RM2UC, SMT3000RMT2U, SMX1000C, SMX1000US, SMX1500RM2UC, SMX1500RM2UCNC, SMX1500RMNCUS, SMX1500RMUS, SMX2000LV, SMX2000LVNC, SMX2000LVNCUS, SMX2000LVUS, SMX2200HV, SMX2200HVNC, SMX2200R2HVNC, SMX2200RMHV2U, SMX2200RMLVUS, SMX3000HV, SMX3000HV-BR, SMX3000HVNC, SMX3000HVT, SMX3000HVTUS, SMX3000LV, SMX3000LV2U-BR, SMX3000LVNC, SMX3000LVNCUS, SMX3000LVUS, SMX3000RMHV2U, SMX3000RMHV2UNC, SMX3000RMLVUS, SMX3KRMLVNCUS, SMX750C, SMX750CNC, SMX750-NMC, SMX750US, SRT1000RMXLA, SRT1000RMXLA-NC, SRT1000RMXLI, SRT10KRMXLI, SRT10RMXLIX806, SRT1500RMXLA, SRT1500RMXLA-NC, SRT5KRMXLT, SRT5KRMXLT-IEC, SRT5KRMXLTUS, SRT5KRMXLW-HW, SRT5KRMXLW-TW, SRT6KRMXLI, SRT6KRMXLT, SRT6KRMXLT-IEC, SRT8KRMXLI, SRT8KRMXLT, SRT8KRMXLT-IEC, SURT3000XLI-ET, SURT5000XLIX438, SYA12K16RMICH, SYA16K16RMICH, SYA8K16RMICH, SYAF16KRMICH, SYAF8KRMTX424 |
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using StruxureWare Data Center Expert, Operations, Capacity, and Energy Efficiency. New AP8000 series Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra-low profile circuit breakers.
- Remote Management Capabilities
- Local Current Monitoring Display
- Alarm Thresholds
- Load indicator LED
- Integrates with StruxureWare Data Center Expert
- Flash Upgradeable
The technical details come from 3rd party. edgemo is not responsible for any errors.