APC Basic Rack-Mount PDU - power distribution strip

SKU AP9565
Product Description:APC Basic Rack-Mount PDU - power distribution strip
Device Type:Power distribution strip - rack-mountable
Cord Length:2.5 m
Rack Size:19" - 1U
Weight:2 kg
Localisation:Belgium, Bahrain, Jordan, Lebanon, United Arab Emirates, Albania, Argentina, Australia, Bulgaria, China, Colombia, Czech Republic, Estonia, Indonesia, Israel, Lithuania, South Africa, Vietnam, Ukraine, Venezuela, Canada, Chile, Egypt, Hong Kong, Mexico, New Zealand, Pakistan, Romania, Thailand, Malaysia, Singapore, Puerto Rico, Luxembourg, Hungary, India, Kenya, Nigeria, Uganda, Tanzania, Bolivia, Uruguay, Peru, Paraguay, Ecuador, Honduras, Guatemala, Costa Rica, Salvador, Panama, Nicaragua, Dominican Republic, Trinidad, Jamaica, Ethiopia, Somalia, Rwanda, Zimbabwe, Philippines, Yugoslavia, Bosnia, Croatia, Macedonia, Slovenia, Korea, Latvia, Herzegovina, Burundi, Djibouti, Netherlands Antilles, Austria, Brazil, Denmark, Finland, France, Germany, Italy, Netherlands, Norway, Poland, Portugal, Russia, Spain, Sweden, Switzerland, United Kingdom, United States, Greece, Turkey, Ireland
Input Voltage:AC 208/230 V
13-05-2024
  • Specifications
  • Description
General
Device Type:Power distribution strip - rack-mountable
Height (Rack Units):1U
Rack Size:19"
Cord Length:2.5 m
Colour:Black
Localisation:Belgium, Bahrain, Jordan, Lebanon, United Arab Emirates, Albania, Argentina, Australia, Bulgaria, China, Colombia, Czech Republic, Estonia, Indonesia, Israel, Lithuania, South Africa, Vietnam, Ukraine, Venezuela, Canada, Chile, Egypt, Hong Kong, Mexico, New Zealand, Pakistan, Romania, Thailand, Malaysia, Singapore, Puerto Rico, Luxembourg, Hungary, India, Kenya, Nigeria, Uganda, Tanzania, Bolivia, Uruguay, Peru, Paraguay, Ecuador, Honduras, Guatemala, Costa Rica, Salvador, Panama, Nicaragua, Dominican Republic, Trinidad, Jamaica, Ethiopia, Somalia, Rwanda, Zimbabwe, Philippines, Yugoslavia, Bosnia, Croatia, Macedonia, Slovenia, Korea, Latvia, Herzegovina, Burundi, Djibouti, Netherlands Antilles, Austria, Brazil, Denmark, Finland, France, Germany, Italy, Netherlands, Norway, Poland, Portugal, Russia, Spain, Sweden, Switzerland, United Kingdom, United States, Greece, Turkey, Ireland
Power Device
Input Voltage:AC 208/230 V
Frequency Provided:50/60 Hz
Frequency Required:50/60 Hz
Input Connectors:1 x power IEC 60320 C20
Power Output Connectors Details:12 x power IEC 60320 C13
Output Voltage:AC 208/230 V 50/60 Hz
Max Electric Current:16 A
Miscellaneous
Cables Included:Power cable - integrated - 2.5 m
Rack Mounting Kit:Included
Compliant Standards:UL, cUL, UL 1363
Manufacturer Warranty
Service & Support:Limited warranty - parts and labour - 2 years
Environmental Parameters
Min Operating Temperature:0 °C
Max Operating Temperature:45 °C
Min Storage Temperature:-25 °C
Max Storage Temperature:65 °C
Humidity Range Operating:0 - 95%
Humidity Range Storage:0 - 95%
Dimensions & Weight
Width:44.7 cm
Depth:5.7 cm
Height:4.5 cm
Weight:2 kg
Compatibility Information
Designed For:P/N: AR106, AR106SH4, AR106SH6, AR109SH4, AR109SH6, AR112, AR112SH4, AR112SH6, AR2487G, AR3003, AR3003SP, AR3006, AR3006SP, AR3100W, AR3103, AR3103SP, AR3105SP, AR3105W, AR3106, AR3106SP, AR3107SP, AR3140G, AR3140W, AR3150SP, AR3150W, AR3155SP, AR3155W, AR3157SP, AR3300SP, AR3300W, AR3305SP, AR3305W, AR3307SP, AR3340G, AR3340W, AR3350SP, AR3350W, AR3355SP, AR3355W, AR3357SP, AR3357X674, AR4018IX429, AR4018SP, AR4018SPX429, AR4018SPX431, AR4018SPX432, AR4018X429, AR4024IX431, AR4024SP, AR4024SPX429, AR4024SPX431, AR4024SPX432, AR4038IX432, AR8213, AR9300SP, AR9300SP-R, AR9307SP, AR9307SP-R, NBPD0160A, NBWL0355A, NBWL0356A, SCL400RMJ1U, SCL500RM1UC, SCL500RM1UNC, SCL500RMI1UC, SCL500RMI1UNC, SMC1000-BR, SMC1000I-2UC, SMC1000I-BR, SMC1000IC, SMC15002U-BR, SMC1500-BR, SMC1500I2U-BR, SMC1500I-2UC, SMC1500I-BR, SMC1500IC, SMC2000I, SMC2000I-2U, SMC3000I, SMT2200I-AR, SMT2200IC, SMT2200R2I-AR, SMT2200RM2UC, SMT2200RMI2UC, SMT2200RMI2UNC, SMT3000I2U-BR, SMT3000I-AR, SMT3000IC, SMT3000R2I-6W, SMT3000R2I-AR, SMT3000RM2UC, SMT3000RMI2UC, SMT3000RMI2UNC, SMTL1000RM2UC, SMTL1000RMI2UC, SMTL750RM2UC, SMTL750RMI2UC, SMX1000C, SMX1000US, SMX1500RM2UC, SMX1500RM2UCNC, SMX1500RMNCUS, SMX1500RMUS, SMX2000LVNCUS, SMX2000LVUS, SMX2200HVNC, SMX2200R2HVNC, SMX2200RMLVUS, SMX3000HV-BR, SMX3000HVTUS, SMX3000LV2U-BR, SMX3000LVNCUS, SMX3000LVUS, SMX3000RMLVUS, SMX3KRMLVNCUS, SMX750C, SMX750CNC, SMX750US, SPD10KCBL, SPD20KCBL, SRT1000RMXLA, SRT1000RMXLA-NC, SRT1000RMXLI, SRT1000RMXLI-NC, SRT10KRMXLT-IEC, SRT10KXLT-IEC, SRT10RMXLIX806, SRT1500RMXLA, SRT1500RMXLA-NC, SRT1500XLI, SRT2200RMXLI, SRT2200RMXLI-NC, SRT2200XLI, SRT2200XLI-KR, SRT3000RMXLI, SRT3000RMXLI-NC, SRT3000RMXLW-IEC, SRT3000XLI, SRT3000XLW-IEC, SRT5KRMXLI-6W, SRT5KRMXLIM, SRT5KRMXLT, SRT5KRMXLT-IEC, SRT5KRMXLTUS, SRT5KRMXLW-TW, SRT6KRMXLI-6W, SRT6KRMXLIM, SRT6KRMXLT, SRT6KRMXLT-IEC, SRT6KXLT-IEC, SRT8KRMXLT, SRT8KRMXLT-IEC, SRT8KXLT-IEC, SUA2200ICH-45, SUA3000I-IN, SYAF16KRMICH
vis mere
Reliable rack power distribution designed to increase manageability and efficiency in the data center The output and input connections are (12)C13 Real-time remote monitoring of connected loads User-defined alarms warn IT and data center managers of potential circuit overloads to prevent accidental power loss to critical equipment.